Starter Solenoid Test

1.Remove the starter.

2.Remove the motor cable (A).

 

3.Check the hold-in coil for continuity between the S terminal and the armature housing (ground). There should be continuity.

  • If there is continuity, go to 4.
  • If there is no continuity, replace the solenoid.

4.Check the pull-in coil for continuity between the S terminal and M terminal. There should be continuity.

  • If there is continuity, the solenoid is OK.
  • If there is no continuity, replace the solenoid.

5.Install the motor cable.

6.Install the starter.