1. | Slide the ATF warmer hoses (A) on the ATF filter (B) until the hose ends contact the filter housing, and secure the hoses with the clips (C) at 6-8 mm (0.24-0.31 in.) (D) from the filter housing.
|
2. | Slide the ATF warmer hoses (E) over the ATF lines (F) until the hoses stop, and secure the hoses with the clip (G) at 6-8 mm (0.24-0.31 in.) (H) from the hose end. |
3. | Slide the ATF warmer hoses (I) over the ATF warmer lines (J) until the hose ends contact the bulge (K), and secure the hoses with the clip (L) at 2-4 mm (0.08-0.16 in.) (M) from the hose end. |