Measure the clearance between the reverse idler gear (A) and the reverse shift fork (B) with a feeler gauge (C). If the clearance is more than the service limit, go to 2.
Standard:
0.20-0.59 mm (0.007-0.024 in.)
Service Limit:
1.3 mm (0.051 in.)
2.
Measure the width of the reverse shift fork.
If the width is not within the standard, replace the reverse shift fork.
If the width is within the standard, replace the reverse gear.