Fuel Line/Quick-Connect Fitting Precautions

The fuel tube/quick-connect fittings (A), (B), (C) connect the fuel rail (D) to fuel feed hose A (E), the fuel feed hose A to fuel feed hose B (F), fuel feed hose B to the fuel line (G), and the fuel line (H) to the fuel tank unit (I). When removing or installing the fuel feed hose, fuel tank unit or fuel tank, it is necessary to disconnect or connect the quick-connect fittings.
Pay attention to the following:

 

 


A disconnected quick-connect fitting can be reconnected, but the retainer on the mating pipe cannot be reused once it has been removed from the pipe. Replace the retainer when:


Location Manufacturer Retainer color Piping diameter 
Tokai Green 6.3 mm (0.3 in.) 
Tokai Blue green 8 mm (0.3 in.) 
Sanoh White 9.5 mm (0.4 in.)