Measure the clearance between the change lever (A) and the select lever (B) with a feeler gauge (C). If the clearance is more than the service limit, go to 2.
Standard:
0.05-0.25 mm (0.002-0.010 in.)
Service Limit:
0.50 mm (0.020 in.)
2.
Measure the groove of the change lever.
If the groove is not within the standard, replace the change lever.
If the groove is within the standard, replace the select lever.