M/T Change Lever Clearance Inspection

1.Measure the clearance between the change lever (A) and the select lever (B) with a feeler gauge (C). If the clearance is more than the service limit, go to 2.

Standard: 0.05-0.25 mm (0.002-0.010 in.) 
Service Limit: 0.50 mm (0.020 in.) 

 

2.Measure the groove of the change lever.

  • If the groove is not within the standard, replace the change lever.
  • If the groove is within the standard, replace the select lever.

Standard: 15.00-15.10 mm (0.591-0.594 in.)